Access Control User Manual - V2000-c Rfid
If you wired a reed switch to terminal 7 (SEN):
| Controller Terminal | Connects To | | :--- | :--- | | 12V+ / GND | Power adapter (12V DC) | | NO / COM | Electric lock (Normally Open) | | NC / COM | Electric lock (Normally Closed) | | PUSH | Exit button (momentary switch) | | D-IN | Door contact/magnetic sensor |
⚠️ Do not apply AC mains directly to the relay terminals.
V2000-C Terminal Block
------------------------------------------------
+12V → Power supply positive
GND → Power supply negative (common ground)
NO → Normally open (to lock’s positive unlock wire)
COM → Common (to lock’s negative / power supply GND)
NC → Normally closed (rarely used with fail-secure locks)
PUSH → Exit button (one side; other side to GND)
SEN → Door contact sensor (to GND when door closed)
ALARM → Optional alarm output
BELL → Optional buzzer output
🔒 Lock type determines wiring:
You now hold the equivalent of an advanced training course for the V2000-c RFID Access Control system. This user manual has walked you from the screw terminals of the relay to the logic of anti-passback and multi-card open.
Final Pro Tips:
For further support, consult your distributor for hardware-level repairs. The V2000-c’s simplicity is its strength – there is no cloud to fail, no subscription fee, and no software to crash. Just security that works.
Document Version: 3.1
Last Updated: [Current Year]
Compatibility: All V2000-c hardware revisions H1.2 and above.
End of the V2000-c RFID Access Control User Manual.
The V2000-C (often branded under Obo Hands or Youhe) is a standalone RFID access control keypad used for single-door security. It supports up to 1,000 users and operates via 125KHz RFID cards, 4-digit PINs, or a combination of both. Quick Setup Guide
To perform any programming, you must first enter Programming Mode.
Enter Programming Mode: Press [*] + [Master Code] (Default: 12345 or 990101) + [#]. Exit Programming Mode: Press [*]. User Management RFID Programming Guide
Introducing the V2000-C RFID Access Control System: A Comprehensive User Manual
Are you looking for a reliable and efficient access control solution for your organization? Look no further than the V2000-C RFID Access Control System. This user manual provides a detailed guide on how to install, configure, and operate the V2000-C system, ensuring that you get the most out of your access control investment.
Overview of the V2000-C System
The V2000-C RFID Access Control System is a cutting-edge solution designed to provide secure and convenient access control for various applications, including office buildings, schools, hospitals, and more. The system utilizes RFID technology to grant authorized individuals access to designated areas, while preventing unauthorized entry.
Key Features of the V2000-C System
Installation and Configuration
The V2000-C system is easy to install and configure, with a user-friendly interface that guides administrators through the process. The system can be integrated with existing security systems, including alarms and CCTV cameras.
Operating the V2000-C System
The V2000-C system is designed to be easy to use, with a simple and intuitive interface that allows administrators to manage access control with ease. The system can be operated using a variety of methods, including:
Troubleshooting and Maintenance
The V2000-C system is designed to be reliable and durable, but like any system, it may require occasional troubleshooting and maintenance. The user manual provides a comprehensive guide on how to troubleshoot common issues and perform routine maintenance tasks.
Conclusion
The V2000-C RFID Access Control System is a powerful and reliable solution for managing access control in various applications. With its user-friendly interface, durable design, and advanced features, the V2000-C system provides a comprehensive access control solution that meets the needs of organizations of all sizes. Download the V2000-C RFID Access Control User Manual today and discover how to get the most out of your access control investment.
V2000-C RFID Access Control User Manual: A Comprehensive Guide
In today's fast-paced world, security and access control have become a top priority for individuals and organizations alike. One of the most effective ways to ensure secure access to a premises or a specific area is by using RFID (Radio Frequency Identification) access control systems. The V2000-C RFID access control system is a popular and widely used solution that offers a high level of security, flexibility, and ease of use.
In this article, we will provide a comprehensive guide to the V2000-C RFID access control system, including its features, installation, configuration, and operation. We will also cover troubleshooting and maintenance tips to ensure optimal performance.
Introduction to V2000-C RFID Access Control System V2000-c Rfid Access Control User Manual
The V2000-C RFID access control system is a cutting-edge solution designed to control access to a specific area or premises. The system uses RFID technology to identify and authenticate individuals with authorized access. The system consists of a control panel, RFID readers, and electronic locks.
The V2000-C system is designed to be flexible and scalable, making it suitable for a wide range of applications, from small offices to large industrial complexes. The system can be configured to support multiple access levels, time zones, and holidays.
Features of V2000-C RFID Access Control System
The V2000-C RFID access control system comes with a range of features that make it an ideal solution for access control. Some of the key features include:
Installation and Configuration
Installing and configuring the V2000-C RFID access control system requires careful planning and attention to detail. Here are the general steps involved in installing and configuring the system:
User Manual and Configuration Guide
The V2000-C RFID access control system comes with a comprehensive user manual that provides detailed instructions on installation, configuration, and operation. Here are some key configuration steps:
Operation and Maintenance
The V2000-C RFID access control system is designed to be easy to operate and maintain. Here are some tips on operating and maintaining the system:
Troubleshooting and FAQs
Here are some common issues and FAQs related to the V2000-C RFID access control system:
Conclusion
The V2000-C RFID access control system is a reliable and effective solution for securing access to a premises or specific area. By following the user manual and configuration guide, administrators can ensure optimal performance and security. Regular maintenance and troubleshooting can help prevent system downtime and ensure smooth operation. If you wired a reed switch to terminal 7 (SEN):
Downloads and Resources
For more information on the V2000-C RFID access control system, please refer to the following resources:
By following this comprehensive guide, administrators can ensure that their V2000-C RFID access control system is installed, configured, and operated correctly, providing a high level of security and access control.
The V2000-C is a standalone RFID access control keypad designed for single-door security. It supports up to 1,000 users and utilizes 125KHz EM standard cards. 1. Core Specifications Operating Voltage: 12VDC ± 10%. Unlock Relay: 12VDC / 2A. Card Type: 125KHz EM standard RFID cards. User Capacity: Up to 1,000 users. Entry Modes: Card only, PIN only, or Card + PIN. 2. Setup and Programming
To perform any administrative tasks, you must first enter Programming Mode.
Enter Programming Mode: Press [*] + [6-digit Programming PIN] (Default is often 123456 or 888122). Two beeps confirm entry.
Change Programming PIN: Press [0] + [New 6-digit PIN] + [Repeat New 6-digit PIN].
Exit Programming Mode: Press [*] or wait for the system to time out. 3. User Management
Most standalone units like the V2000-C use numeric commands for management: Add RFID Card: Enter Programming Mode. Press [5] + [4-digit User ID] (e.g., 0001). Present the RFID card to the reader (you will hear a beep). Press [#] to confirm. Delete RFID Card: By Card: Press [7] + [Present Card] + [#]. By User ID: Press [6] + [4-digit User ID] + [#]. Add Public PIN: Press [3] + [4-digit Public PIN] + [#]. 4. System Settings
Door Open Duration: Press [2] + [Time in seconds (00-99)] + [#] (e.g., 05 for 5 seconds). Set Access Mode: Card or PIN (Default): Press [4] + [0] + [#]. Card and PIN: Press [4] + [1] + [#]. 5. Resetting to Factory Defaults
If you lose the master code, you can typically reset the system using an internal jumper. Power off the device.
Move the internal jumper (often labeled JP4 or S16) to pins 1-2. Power the device on and wait for the beeps. Power off again and move the jumper back to pins 2-3.
For further technical support or visual wiring diagrams, refer to the Obohands Download Center or Scribd's Programming Manual.
V2000-C Standalone access controller system for single door access Relay Outputs:
Note: The exact manual may vary slightly by firmware version. The following is a synthesized, practical guide based on standard features of the V2000-C series.