Error codes on the Schindler 5500 system are designed to help technicians and maintenance personnel quickly identify and address problems. These codes can indicate a range of issues, from minor faults that can be easily corrected to more serious problems requiring immediate attention.
Note: This should only be performed by authorized personnel.
On the serial communication board or the LCBII (Logistic Control Board), you can often navigate the menu using the LCD display or LED segments.
This guide is a free resource for educational and reference purposes. Schindler does not publish complete error code lists publicly; the codes above are compiled from field service manuals and technician experience. Always follow your local safety regulations and your company’s lockout/tagout procedures before opening any elevator control panel.
For the most recent or model-specific codes (e.g., 5500 XL, 5500 MRL), contact your regional Schindler support office with your exact unit serial number.
Decoding the error codes for the Schindler 5500 elevator is critical for maintaining its high-performance, modular design. These codes, typically displayed on the SMLCD (Schindler Machine LCD) or a diagnostic tool, serve as the primary communication between the system's complex sensors and the technician. Common Schindler 5500 Error Codes
The following codes are frequently encountered during maintenance of the 5500 and 6500 series:
0013 (Overspeed): The system has detected the car moving beyond its rated speed limit.
0019 (Watchdog Reset): A processor problem was detected, forcing the system to restart automatically.
0033 (Start-up / Manual Reset): Indicates the system was recently reset, either by a user command (101) or after an earthquake mode recovery.
0441 (Drive Overtemperature): The drive unit has exceeded its safe operating temperature; the car will typically finish its current run and then stop.
0450 (Releveling Failure): The car failed to level correctly at a floor, often due to a bad leveling sensor or exceeding the allowed leveling distance.
1105 - 1112 (Load Weigh Device): Indicates the load weighing system requires calibration.
TMMB Fault: Often caused by incorrect system date/time settings, which can interfere with the monitoring of the traction media (belts). Primary Troubleshooting Steps
When addressing these faults, technicians typically follow a tiered diagnostic approach:
Verify the Status Code: On the diagnostic screen, a status of 01 indicates normal automatic operation. Any other value signifies the elevator is in a restricted state (e.g., inspection or fire recall).
Perform a System Reset: Many intermittent software glitches can be cleared using a Single Reset (pressing the reset button on the GCIOCF board once) or a Double Reset for full re-initialization.
Check Safety Circuits: Faults like "Safety circuit open" or DLM (Door Lock Monitor) errors prevent the car from moving if door locks or gate switches are bypassed or malfunctioning.
Inspect Battery Systems: Errors like PeboBat often relate to the TSU (Terminal Sub-module Unit) batteries in the hoistway, which may need replacement if they fail their periodic self-check.
For comprehensive technical documentation, technicians often refer to the Schindler 5500 Commissioning Manual or specific error logs for the 5500/6500 series.
This guide is provided for educational and reference purposes only. Elevator maintenance and repair should only be performed by qualified and licensed elevator technicians. Tampering with elevator controls without proper training can result in severe injury, death, or significant property damage. Always consult the official Schindler technical manuals for your specific serial number.
| Code | Description | Likely Cause | Action | |------|-------------|--------------|--------| | 5001 | CAN bus off (drive to control) | Wiring issue, terminated incorrectly | Check CAN bus termination resistors (120Ω) | | 5010 | Serial link to car lost | Traveling cable damage, loose connector | Inspect traveling cable for breaks | | 5102 | Group communication fault | Failed group controller or bad LAN connection | Reset group controller, check Ethernet switch |
When dealing with elevator systems, safety should always be the top priority. Incorrectly diagnosing or attempting to fix errors without proper knowledge can lead to serious accidents. Always ensure that any work on the Schindler 5500 or any other elevator system is performed by qualified professionals.
While specific, detailed documentation might be proprietary and restricted to authorized personnel or customers, there are a few strategies you can use to find information on Schindler 5500 error codes:
9 Comments
Join the discussion and tell us your opinion.
Free - Schindler 5500 Error Codes
Error codes on the Schindler 5500 system are designed to help technicians and maintenance personnel quickly identify and address problems. These codes can indicate a range of issues, from minor faults that can be easily corrected to more serious problems requiring immediate attention.
Note: This should only be performed by authorized personnel.
On the serial communication board or the LCBII (Logistic Control Board), you can often navigate the menu using the LCD display or LED segments.
This guide is a free resource for educational and reference purposes. Schindler does not publish complete error code lists publicly; the codes above are compiled from field service manuals and technician experience. Always follow your local safety regulations and your company’s lockout/tagout procedures before opening any elevator control panel.
For the most recent or model-specific codes (e.g., 5500 XL, 5500 MRL), contact your regional Schindler support office with your exact unit serial number.
Decoding the error codes for the Schindler 5500 elevator is critical for maintaining its high-performance, modular design. These codes, typically displayed on the SMLCD (Schindler Machine LCD) or a diagnostic tool, serve as the primary communication between the system's complex sensors and the technician. Common Schindler 5500 Error Codes
The following codes are frequently encountered during maintenance of the 5500 and 6500 series: schindler 5500 error codes free
0013 (Overspeed): The system has detected the car moving beyond its rated speed limit.
0019 (Watchdog Reset): A processor problem was detected, forcing the system to restart automatically.
0033 (Start-up / Manual Reset): Indicates the system was recently reset, either by a user command (101) or after an earthquake mode recovery.
0441 (Drive Overtemperature): The drive unit has exceeded its safe operating temperature; the car will typically finish its current run and then stop.
0450 (Releveling Failure): The car failed to level correctly at a floor, often due to a bad leveling sensor or exceeding the allowed leveling distance.
1105 - 1112 (Load Weigh Device): Indicates the load weighing system requires calibration. Error codes on the Schindler 5500 system are
TMMB Fault: Often caused by incorrect system date/time settings, which can interfere with the monitoring of the traction media (belts). Primary Troubleshooting Steps
When addressing these faults, technicians typically follow a tiered diagnostic approach:
Verify the Status Code: On the diagnostic screen, a status of 01 indicates normal automatic operation. Any other value signifies the elevator is in a restricted state (e.g., inspection or fire recall).
Perform a System Reset: Many intermittent software glitches can be cleared using a Single Reset (pressing the reset button on the GCIOCF board once) or a Double Reset for full re-initialization.
Check Safety Circuits: Faults like "Safety circuit open" or DLM (Door Lock Monitor) errors prevent the car from moving if door locks or gate switches are bypassed or malfunctioning.
Inspect Battery Systems: Errors like PeboBat often relate to the TSU (Terminal Sub-module Unit) batteries in the hoistway, which may need replacement if they fail their periodic self-check. This guide is a free resource for educational
For comprehensive technical documentation, technicians often refer to the Schindler 5500 Commissioning Manual or specific error logs for the 5500/6500 series.
This guide is provided for educational and reference purposes only. Elevator maintenance and repair should only be performed by qualified and licensed elevator technicians. Tampering with elevator controls without proper training can result in severe injury, death, or significant property damage. Always consult the official Schindler technical manuals for your specific serial number.
| Code | Description | Likely Cause | Action | |------|-------------|--------------|--------| | 5001 | CAN bus off (drive to control) | Wiring issue, terminated incorrectly | Check CAN bus termination resistors (120Ω) | | 5010 | Serial link to car lost | Traveling cable damage, loose connector | Inspect traveling cable for breaks | | 5102 | Group communication fault | Failed group controller or bad LAN connection | Reset group controller, check Ethernet switch |
When dealing with elevator systems, safety should always be the top priority. Incorrectly diagnosing or attempting to fix errors without proper knowledge can lead to serious accidents. Always ensure that any work on the Schindler 5500 or any other elevator system is performed by qualified professionals.
While specific, detailed documentation might be proprietary and restricted to authorized personnel or customers, there are a few strategies you can use to find information on Schindler 5500 error codes:
Thank you Justin !
Thank you Jarod, you can mail me at .
Wow that was odd. I just wrote an really long comment but after I clicked submit my comment didn’t appear.
Grrrr… well I’m not writing all that over again. Anyhow, just
wanted to say excellent blog!
Your means of explaining everything in this article is
genuinely good, every one be capable of simply be aware of it, Thanks a
lot.
Your style is unique in comparison to other folks I have read stuff from.
Thanks for posting when you’ve got the opportunity, Guess
I will just bookmark this page.
Thank you Jeffry !
Hello, just wanted to say, I loved this article.
It was funny. Keep on posting!
Thanks for the kind message