The Gilbarco SK700 Programming Manual typically covers:
Before diving into the manual itself, it's important to understand the hardware. The SK700 is an electronic dispenser control console designed for:
It manages up to 16 fueling positions (hoses), integrates with submersible pumps, handles authorization (card readers or remote POS), and logs transaction data. The programming manual is the blueprint for configuring all of these functions.
Detailed Error Code Reference
A full table of LED blink codes and display messages is provided. This is the manual’s most valuable section for diagnosing failing pumps.
Step-by-Step Calibration
For volumetric calibration (adjusting for temperature, wear, etc.), the manual gives exact flow counter constants and factor-adjustment procedures.
Wiring & Pinout Diagrams
Clear schematics for the CPU board, solenoid drive outputs, and pulse-input connectors. Essential for retrofits or repairs.
| Step | Action |
|------|--------|
| 1️⃣ | Connect & launch the host software (as above). |
| 2️⃣ | Backup configuration. |
| 3️⃣ | Go to Configuration → Nozzle Mapping. You’ll see a table: Nozzle #, Grade Code, Physical ID, Status. |
| 4️⃣ | Click Add. Enter the new nozzle number, assign the correct Grade Code (e.g., “DSL” for Diesel), and set Status = Active. |
| 5️⃣ | If the new nozzle is a remote (e.g., a hose from a secondary manifold), you may need to edit the I/O Mapping page to define its hardware address. |
| 6️⃣ | Validate, then Upload the configuration. |
| 7️⃣ | Perform a Nozzle Self‑Test from the host (Diagnostics → Nozzle Test). The software will energize the solenoid and confirm closure/opening. |
| 8️⃣ | Re‑boot and confirm that the pump now displays the new grade on the affected nozzle. |
| Prerequisite | You must have a firmware package that matches the hardware revision (e.g., “SK‑700‑FW‑V5.12‑Rev‑B”). | |--------------|------------------------------------------------------| | 1️⃣ | Connect via Ethernet (preferred for large files). | | 2️⃣ | In the host software, go to Tools → Firmware Update. | | 3️⃣ | Select the appropriate .bin/.hex file. | | 4️⃣ | The tool will first upload the bootloader (if required) and then the application image. | | 5️⃣ | Do NOT power‑cycle the dispenser until the process completes. The UI will show progress bars for each stage. | | 6️⃣ | When finished, the dispenser will auto‑reboot. Verify the new firmware version under System → Info. | | 7️⃣ | Re‑apply any custom configuration (price tables, nozzle maps) that may have been cleared by a full firmware flash. |
Programming a device like the Gilbarco SK700 requires a detailed understanding of its technical specifications, the site's operational requirements, and compliance with relevant security standards. Always refer to the official documentation and seek support from the manufacturer or qualified professionals if needed.
Gilbarco SK700 fuel dispensers utilize a hierarchical command structure for programming, typically accessed via a manager keypad. 1. Programming Access and Security
Access to programming functions is divided into security levels, each requiring a specific code to prevent unauthorized changes.
Level 2 (Manager Mode): Used for common configurations like pump numbers. The standard security code is 1503.
Level 4 (Technician Mode): Required for critical parameter changes like pulse scales. The common security code is 0128. 2. Common Configuration Commands
Programming is performed using Command Codes (CC) followed by specific values.
CC 24 – Operation Mode: Defines how the dispenser communicates with the forecourt: 24 -> 1: 2-Wire 24 -> 2: Stand Alone 24 -> 3: IFSF 1.51 - LON
CC 40 – Pump Identity: Sets the pump numbers for 2-Wire communication.
CC 5 – Real-Time Display: Configures what is shown during delivery: 40.5 -> 1: Displays real-time Money. 40.5 -> 2: Displays real-time Volume.
CC 6 – Volume Pulse Scale: Sets the measurement resolution (e.g., 10, 50, or 100 pulses/litre).
CC 8 – Auto Authorization: Enables (1) or disables (2) automatic pump authorization. 3. Operational Procedures
Warm Start: To restart the dispenser or clear minor software errors without losing settings, press F1 + F2 on the Manager Keypad. Cold Start (Apollo CPU):
For a complete reset or hardware replacement, you must move the internal "CAL" switch to the left, insert a "Cold Start" link, and power up the unit. A flashing E 9 on the display confirms a successful cold start. USB Configuration: For newer
models, you can use a special USB stick to "Get Config" (Command 8) or upload new software by inserting it and performing a cold start. 4. Error Diagnostics Errors are displayed as codes in the unit price display. E 60: Internal totalizer reset to zero.
5131: Preset keypad enabled but not detected; check connections.
5154: Printer paper out (for dispensers with integrated receipts).
For detailed step-by-step procedures, you can reference the SK700 II Programming Parameters Guide or the Installation and Commissioning Manual from Gilbarco Veeder-Root. To help you with the specific steps, could you tell me: SK700 II Programming Parameters Guide | PDF - Scribd
30 May 2008 — Set Real time Volume – Function Code 5. 40.5 -> 1 Real time Money. 40.5 -> 2 Real time Volume. 25-02.09E_ENGLISCH.DOC 30.05.2008 - SK700 II Programming Parameters Guide | PDF - Scribd
Gilbarco SK700 programming manual is a technical document used by field service technicians to configure dispenser parameters, perform cold starts, and troubleshoot hardware. Essential Programming Codes
Programming is typically performed via the managerial keypad using specific security levels: Level 0 (0000): Basic access. Level 1 (2222): Set Price Per Unit (PPU) [Command Code 20]. Level 4 (0128): Master access for core system changes. Command Code Options/Action PPU (Price) Select Side (1, 2, or 3 for both) then Grade. Operation Mode 1 = Two-wire (remote); 2 = Standalone. Volume Allocation Set max volume limit per transaction. Pump Beeper Enable or disable the keypad/transaction beeper. Display Test Adjust segment lamp test time (default is 3s). Cold Start & Initial Setup
A cold start is required for major reconfigurations or after replacing the CPU board: Hardware Access: Open the CPU board cover. Toggle Switch: Move the switch to the CAL position. Jumper: Move the jumper to the Cold Start position. Power Up: The display will show a flashing E9.
Enter Codes: Press F1, enter master code 0128, and press Enter.
Basic Parameters: You must set the country code, pump type, pump numbers, and protocol. Troubleshooting Quick Reference Common error codes seen on the unit price display: E1 / E35: Database or configuration error. E5 / E5034: Software cold start executed. E9 / 5035: Hardware cold start jumper is active.
Code 11: Two-wire communication lost between pump and controller. Code 20: Pulser disconnected or not mapped correctly. Code 33: Emergency Stop (E-Stop) button activated.
Detailed error logs can be requested directly from Gilbarco Veeder-Root or specialized repair centers like Kentronics. If you'd like, I can:
Give you the exact steps for a specific code (like changing the PPU).
Provide a deeper breakdown of error codes for a specific issue (e.g., leaks or communication failure).
Help you find a PDF version of a specific sub-manual (like for the Apollo CPU or LPG units). What is the current issue or task you are working on?
Gilbarco Sk700 Programming Manual Report
Introduction
The Gilbarco Sk700 is a popular point-of-sale (POS) system used in various retail fueling environments, including convenience stores and gas stations. The system is designed to manage fuel sales, inventory, and customer transactions efficiently. This report provides an overview of the Gilbarco Sk700 programming manual, highlighting its key features, programming procedures, and troubleshooting guidelines.
Overview of the Gilbarco Sk700 System
The Gilbarco Sk700 system consists of a central processing unit (CPU), a user interface, and various peripherals, such as fuel dispensers, payment terminals, and printers. The system runs on a proprietary operating system and is programmed using a specific set of commands and procedures.
Programming Manual Structure
The Gilbarco Sk700 programming manual is organized into several sections, including:
Key Programming Procedures
Some key programming procedures covered in the manual include:
Programming Commands
The manual provides a comprehensive list of programming commands used to configure and manage the Sk700 system. Some common commands include:
Troubleshooting Guidelines
The manual provides troubleshooting guidelines for common issues and errors that may occur during programming or system operation. Some common troubleshooting procedures include:
Conclusion
The Gilbarco Sk700 programming manual provides a comprehensive guide to programming and managing the Sk700 POS system. The manual covers key programming procedures, command references, and troubleshooting guidelines, making it an essential resource for system administrators, programmers, and technicians. By following the guidelines and procedures outlined in the manual, users can ensure efficient and effective operation of the Sk700 system.